The spine
Trace commodity
Paste a serial or batch identifier to resolve the full custody chain, from batch release through each custody hop to dispense, verification and client follow-up.
Try a pack
Resolved pack
RDT08-031671
Malaria rapid diagnostic test, Single test, ADMFm pack from lot LOT-NAS2606-08
Attention: In the distribution chain
- Events in chain
- 7
- Nodes verified
- 7 of 7
- Exceptions
- 1
- First event
- 2026-05-21
- Last event
- 2026-07-16
- Batch
- BAT-08
This pack has not reached an outlet. It currently sits with the buyer named at the last custody hop.
- 01Exception
Counterfeit alert raised
Yerima Medicine Store, outlet
2026-05-21 15:24:00 UTC+01Jere, BornoAttention: ExceptionPass: Verified- Trigger
- Verification returned a code already used
- Channel
- Sproxil app scan
- Severity
- High
- NAFDAC reference
- NAFDAC-INV-2026-0700
- Outcome
- Confirmed counterfeit
- Action taken
- Batch quarantined, NAFDAC enforcement notified, supplier delisted
- Status
- Resolved
- 02Manufacture and release
Batch released by manufacturer
NASENI, manufacturer
2026-07-04 08:16:00 UTC+01Abuja Municipal, Federal Capital TerritoryPass: Verified- Lot
- LOT-NAS2606-08
- QA certificate
- QA-NAS2606-08
- QA laboratory
- NAFDAC Central Drug Control Laboratory, Yaba
- Quantity released
- 46,000
- Expiry
- 2028-06-26
- NAFDAC status
- Approval pathway
- GMP status
- In progress
- 03Serial activation
Serial range activated
NASENI, manufacturer
2026-07-04 09:57:00 UTC+01Abuja Municipal, Federal Capital TerritoryPass: Verified- Serial range
- RDT08-000001 to RDT08-046000
- Serials committed
- 46,000
- Scheme
- GS1 GTIN plus serial, Sproxil Verify for mRDT, Sproxil MAS for ACT
- GS1 element string
- (01)06150100001231(21)RDT08-000001(10)NAS2606-08(17)280626
- Method
- Serial range committed to the traceability register at QA release
- 04Custody transfer
Consignment dispatched
NASENI, manufacturer
2026-07-08 11:57:00 UTC+01Abuja Municipal, Federal Capital TerritoryPass: Verified- Hop
- Manufacturer to first line buyer
- Consigned to
- Savannah Medical Supplies
- Consignment
- CON-0092
- SSCC
- 61500000001000092
- Waybill
- WB-000092
- Quantity
- 46,000
- Serial range
- RDT08-000001 to RDT08-046000
Consignment received and scanned
Savannah Medical Supplies, first line buyer
2026-07-11 09:20:00 UTC+01GPS11.914115, 13.182866Jere, BornoPass: Verified- Consignment
- CON-0092
- SSCC
- 61500000001000092
- Quantity expected
- 46,000
- Quantity received
- 46,000
- Validated
- Yes
- Validation method
- Scan of consignment SSCC against dispatch record
Consignment dispatched
Savannah Medical Supplies, first line buyer
2026-07-12 09:52:00 UTC+01Jere, BornoPass: Verified- Hop
- First line buyer to second line buyer
- Consigned to
- Jere Medical Wholesale Stores
- Consignment
- CON-0100
- SSCC
- 61500000001000100
- Waybill
- WB-000100
- Quantity
- 3,450
- Serial range
- RDT08-029900 to RDT08-033349
Consignment received and scanned
Jere Medical Wholesale Stores, second line buyer
2026-07-16 14:26:00 UTC+01GPS11.923357, 13.186469Jere, BornoPass: Verified- Consignment
- CON-0100
- SSCC
- 61500000001000100
- Quantity expected
- 3,450
- Quantity received
- 3,450
- Validated
- Yes
- Validation method
- Scan of consignment SSCC against dispatch record
The outlet axis onto the same events is the outlet profile.